  "schema_version": 2,
  "authority": "Dennis Campbell source specification; manufacturer source/reference/product-manifest.json is the canonical interpreted catalog.",
  "verified_definition": "VERIFIED_SPEC_SOURCE means documented in the supplied source, not independently tested, certified, available for order, or approved engineering selection.",
  "row_coverage": "97 retained interpreted rows, not a complete enumeration of every printed line. Ambiguous or omitted identities remain in the 16 original source pages; no additional product identity is inferred.",
  "source_families": [
    {
      "code": "PBSM",
      "name": "Vertical water-to-air \u2014 largest single-compressor",
      "page": 1,
      "cabinet": {
        "width_in": 28,
        "depth_in": 36,
        "height_in": 64
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 \u00d7 36 \u00d7 64 inch dimensions and flag the source discrepancy here."
      ]
    },
    {
      "code": "PBVE",
      "name": "Vertical water-to-air \u2014 standard single-compressor",
      "page": 2,
      "cabinet": {
        "width_in": 28,
        "depth_in": 34,
        "height_in": 59
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": []
    },
    {
      "code": "PBMC",
      "name": "Vertical water-to-air \u2014 compact",
      "page": 3,
      "cabinet": {
        "width_in": 26,
        "depth_in": 26,
        "height_in": 54
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "code": "PBSC",
      "name": "Vertical water-to-air \u2014 scroll compressor",
      "page": 4,
      "cabinet": {
        "width_in": 24,
        "depth_in": 24,
        "height_in": 46
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": []
    },
    {
      "code": "PBRC",
      "name": "Condo water-to-air with built-in HRV",
      "page": 5,
      "cabinet": {
        "width_in": 22,
        "depth_in": 26,
        "height_in": 72
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "Heading says PBRC; cabinet heading says PBCD-72; rows are labelled PBSC and cannot be safely normalized."
      ]
    },
    {
      "code": "PBHS",
      "name": "Horizontal split water-to-air \u2014 large",
      "page": 6,
      "cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "alternate_cabinet": null,
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "conflicts": []
    },
    {
      "code": "PHHS",
      "name": "Horizontal split water-to-air \u2014 standard",
      "page": 7,
      "cabinet": {
        "width_in": 36,
        "depth_in": 36,
        "height_in": 28
      },
      "alternate_cabinet": null,
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "conflicts": []
    },
    {
      "code": "PBHO/PHHO",
      "name": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "page": 8,
      "cabinet": {
        "width_in": 72,
        "depth_in": 32,
        "height_in": 28
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "code": "PBHC",
      "name": "One-cabinet horizontal water-to-air \u2014 compact",
      "page": 9,
      "cabinet": {
        "width_in": 66,
        "depth_in": 28,
        "height_in": 26
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "code": "PBST",
      "name": "Vertical water-to-air triple function",
      "page": 10,
      "cabinet": {
        "width_in": 28,
        "depth_in": 36,
        "height_in": 65
      },
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": []
    },
    {
      "code": "PBHT",
      "name": "Horizontal water-to-air triple function",
      "page": 11,
      "cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "alternate_cabinet": null,
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "code": "PBWW",
      "name": "Water-to-water",
      "page": 12,
      "cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "alternate_cabinet": {
        "width_in": 36,
        "depth_in": 36,
        "height_in": 26
      },
      "secondary_cabinet": null,
      "conflicts": []
    },
    {
      "code": "PBWW-WWA",
      "name": "Water-to-water-to-air",
      "page": 13,
      "cabinet": null,
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "Source reuses PBWW identifiers and lists four possible cabinet styles without mapping any model to a cabinet."
      ]
    },
    {
      "code": "PWWT",
      "name": "Water-to-water triple function",
      "page": 14,
      "cabinet": null,
      "alternate_cabinet": null,
      "secondary_cabinet": null,
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "code": "PBDH",
      "name": "Indoor-pool dehumidification",
      "page": 15,
      "cabinet": {
        "width_in": 36,
        "depth_in": 36,
        "height_in": 65
      },
      "alternate_cabinet": {
        "width_in": 36,
        "depth_in": 34,
        "height_in": 59
      },
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "code": "PASD",
      "name": "Heating, cooling and absolute dehumidification",
      "page": 16,
      "cabinet": {
        "width_in": 36,
        "depth_in": 36,
        "height_in": 64
      },
      "alternate_cabinet": {
        "width_in": 36,
        "depth_in": 34,
        "height_in": 59
      },
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    }
  ],
  "source_sha256": {
    "reference/product-manifest.json": "9658ea59e47bd222fd385728dc3efa71e5209e07662a2ffe536dca0623894d8d",
    "reference/heat-pumps-manufactured.txt": "10f003565bcd14855f847bd496a8929ae1f7463fb13e0ce1d05fd5ab5c8ccdcc",
    "reference/dennis-product-specifications.pdf": "854c784cebc43728eec0714e344e9385541307fe212184e1c5f4db8746222ec6",
    "renders/render-map.json": "361c9656b87aff17569336f651b087dcc1241ba3cb69f0475648ecb814b9ff54",
    "photos/photo-manifest.json": "aaaf4e60b4404fc5d539e1d71e2bfed204ab2da1a7255693a68bcb78c27e0181"
  },
  "counts": {
    "source_rows": 97,
    "documented_models": 52,
    "open_rows": 45,
    "exact_model_images": 0
  },
  "models": [
    {
      "row_id": "p01-001-pbsm-96ds12k20",
      "family": "PBSM",
      "model": "PBSM-96DS12K20",
      "configuration": "Vertical water-to-air \u2014 largest single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 1,
      "evidence": "[DC-HPM-p1:model-table] [DC-HPM-p1:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 1,
        "page_text": "sources/pages/page-01.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 96000,
          "heat_32f_btu": 82000,
          "cool_50f_btu": 98000,
          "cool_70f_btu": 92000,
          "cop_50f": "4.0",
          "cop_32f": "3.6",
          "source_seer_50f": "16.8",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 64
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-shop-front.jpg",
      "representative_image_sha256": "7f6c91d1f517591387ea5a94fea6d8507f437923b413fc390fdd823df28776b1",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsm",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            64
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 \u00d7 36 \u00d7 64 inch dimensions and flag the source discrepancy here."
      ]
    },
    {
      "row_id": "p01-002-pbsm-78ds12k20",
      "family": "PBSM",
      "model": "PBSM-78DS12K20",
      "configuration": "Vertical water-to-air \u2014 largest single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 1,
      "evidence": "[DC-HPM-p1:model-table] [DC-HPM-p1:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 1,
        "page_text": "sources/pages/page-01.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 78000,
          "heat_32f_btu": 68000,
          "cool_50f_btu": 84000,
          "cool_70f_btu": 78000,
          "cop_50f": "4.2",
          "cop_32f": "3.8",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.4"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 64
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-shop-front.jpg",
      "representative_image_sha256": "7f6c91d1f517591387ea5a94fea6d8507f437923b413fc390fdd823df28776b1",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsm",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            64
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 \u00d7 36 \u00d7 64 inch dimensions and flag the source discrepancy here."
      ]
    },
    {
      "row_id": "p01-003-pbsm-68ds12k20",
      "family": "PBSM",
      "model": "PBSM-68DS12K20",
      "configuration": "Vertical water-to-air \u2014 largest single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 1,
      "evidence": "[DC-HPM-p1:model-table] [DC-HPM-p1:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 1,
        "page_text": "sources/pages/page-01.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 50000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 68000,
          "heat_32f_btu": 60000,
          "cool_50f_btu": 74000,
          "cool_70f_btu": 68000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 64
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-shop-front.jpg",
      "representative_image_sha256": "7f6c91d1f517591387ea5a94fea6d8507f437923b413fc390fdd823df28776b1",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsm",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            64
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 \u00d7 36 \u00d7 64 inch dimensions and flag the source discrepancy here."
      ]
    },
    {
      "row_id": "p01-004-pbsm-64ds12k20",
      "family": "PBSM",
      "model": "PBSM-64DS12K20",
      "configuration": "Vertical water-to-air \u2014 largest single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 1,
      "evidence": "[DC-HPM-p1:model-table] [DC-HPM-p1:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 1,
        "page_text": "sources/pages/page-01.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 64000,
          "heat_32f_btu": 56000,
          "cool_50f_btu": 70000,
          "cool_70f_btu": 64000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 64
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-shop-front.jpg",
      "representative_image_sha256": "7f6c91d1f517591387ea5a94fea6d8507f437923b413fc390fdd823df28776b1",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsm",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            64
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 1 heading describes a 65-inch cabinet, while its dimensional line states H64 inches. Product pages show the explicit 28 \u00d7 36 \u00d7 64 inch dimensions and flag the source discrepancy here."
      ]
    },
    {
      "row_id": "p02-005-pbve-64ds12k20",
      "family": "PBVE",
      "model": "PBVE-64DS12K20",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 42000,
          "heat_32f_btu": 38000,
          "cool_50f_btu": 47000,
          "cool_70f_btu": 43000,
          "cop_50f": "4.2",
          "cop_32f": "3.7",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.8"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 64000,
          "heat_32f_btu": 56000,
          "cool_50f_btu": 70000,
          "cool_70f_btu": 64000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-006-pbve-60ds12k20",
      "family": "PBVE",
      "model": "PBVE-60DS12K20",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 60000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 66000,
          "cool_70f_btu": 60000,
          "cop_50f": "4.1",
          "cop_32f": "3.7",
          "source_seer_50f": "17.2",
          "source_seer_70f": "16.3"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-007-pbve-56ds12k15",
      "family": "PBVE",
      "model": "PBVE-56DS12K15",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 37000,
          "heat_32f_btu": 34000,
          "cool_50f_btu": 40000,
          "cool_70f_btu": 37000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 56000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 60000,
          "cool_70f_btu": 56000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-008-pbve-55ds12k15",
      "family": "PBVE",
      "model": "PBVE-55DS12K15",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 55000,
          "heat_32f_btu": 49000,
          "cool_50f_btu": 59000,
          "cool_70f_btu": 55000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-009-pbve-48ds12k15",
      "family": "PBVE",
      "model": "PBVE-48DS12K15",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 48000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 49000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-010-pbve-46ds12k15",
      "family": "PBVE",
      "model": "PBVE-46DS12K15",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 31000,
          "heat_32f_btu": 26000,
          "cool_50f_btu": 31000,
          "cool_70f_btu": 29000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 38000,
          "cool_50f_btu": 47000,
          "cool_70f_btu": 44000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-011-pbve-40ds12k10",
      "family": "PBVE",
      "model": "PBVE-40DS12K10",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 26000,
          "heat_32f_btu": 23000,
          "cool_50f_btu": 28000,
          "cool_70f_btu": 26000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 40000,
          "heat_32f_btu": 34000,
          "cool_50f_btu": 42000,
          "cool_70f_btu": 38000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p02-012-pbve-34s12k10",
      "family": "PBVE",
      "model": "PBVE-34S12K10",
      "configuration": "Vertical water-to-air \u2014 standard single-compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 2,
      "evidence": "[DC-HPM-p2:model-table] [DC-HPM-p2:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 2,
        "page_text": "sources/pages/page-02.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 24000,
          "heat_32f_btu": 20000,
          "cool_50f_btu": 24000,
          "cool_70f_btu": 23000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 34000,
          "heat_32f_btu": 30000,
          "cool_50f_btu": 36000,
          "cool_70f_btu": 34000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-installed.jpg",
      "representative_image_sha256": "e79cc6464b11b192e0cbbeb78adea556323c1250ece96c7c6a4098604b73b161",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbve",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            34,
            59
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p03-013-pbmc-36s6k10",
      "family": "PBMC",
      "model": "PBMC-36S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 36000,
          "heat_32f_btu": 30000,
          "cool_50f_btu": 38000,
          "cool_70f_btu": 34000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p03-014-pbmc-35s6k10",
      "family": "PBMC",
      "model": "PBMC-35S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 23000,
          "heat_32f_btu": 19000,
          "cool_50f_btu": 24000,
          "cool_70f_btu": 22000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 35000,
          "heat_32f_btu": 29000,
          "cool_50f_btu": 37000,
          "cool_70f_btu": 33000,
          "cop_50f": "4.2",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p03-015-pbmc-32s6k10",
      "family": "PBMC",
      "model": "PBMC-32S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 32000,
          "heat_32f_btu": 27000,
          "cool_50f_btu": 34000,
          "cool_70f_btu": 30000,
          "cop_50f": "4.2",
          "cop_32f": "3.9",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.8"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p03-016-pbmc-30s6k10",
      "family": "PBMC",
      "model": "PBMC-30S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 31000,
          "heat_32f_btu": 26000,
          "cool_50f_btu": 33000,
          "cool_70f_btu": 29000,
          "cop_50f": "4.4",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 21000,
          "heat_32f_btu": 17000,
          "cool_50f_btu": 22000,
          "cool_70f_btu": 19000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p03-017-pbmc-28s6k10",
      "family": "PBMC",
      "model": "PBMC-28S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 28000,
          "heat_32f_btu": 23000,
          "cool_50f_btu": 30000,
          "cool_70f_btu": 27000,
          "cop_50f": "4.4",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 19000,
          "heat_32f_btu": 15000,
          "cool_50f_btu": 20000,
          "cool_70f_btu": 17000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p03-018-pbmc-26s6k10",
      "family": "PBMC",
      "model": "PBMC-26S6K10",
      "configuration": "Vertical water-to-air \u2014 compact",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 3,
      "evidence": "[DC-HPM-p3:model-table] [DC-HPM-p3:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 3,
        "page_text": "sources/pages/page-03.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 26000,
          "heat_32f_btu": 22000,
          "cool_50f_btu": 28000,
          "cool_70f_btu": 25000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 26,
          "depth_in": 26,
          "height_in": 54
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-open.jpg",
      "representative_image_sha256": "46ec8aaf28dfda3aae3763061656530096880ca281f843ca2341c47d04a972e0",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbmc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            26,
            26,
            54
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "The page 3 Step-1/Step-2 order is inconsistent across PBMC models: PBMC-35 Step 1 is the lower capacity, while PBMC-30 and PBMC-28 Step 1 are the higher capacity. Product pages preserve the printed stage labels and values."
      ]
    },
    {
      "row_id": "p04-019-pbsc-26dk5",
      "family": "PBSC",
      "model": "PBSC-26DK5",
      "configuration": "Vertical water-to-air \u2014 scroll compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 4,
      "evidence": "[DC-HPM-p4:model-table] [DC-HPM-p4:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 4,
        "page_text": "sources/pages/page-04.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 26000,
          "heat_32f_btu": 22000,
          "cool_50f_btu": 28000,
          "cool_70f_btu": 25000,
          "cop_50f": "4.4",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 17000,
          "heat_32f_btu": 15000,
          "cool_50f_btu": 19000,
          "cool_70f_btu": 17000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 24,
          "depth_in": 24,
          "height_in": 46
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-closeup.jpg",
      "representative_image_sha256": "a0d4b7f171affdb20d23a029810214cd3d416d638625ff76f70c385fe127ecd6",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            24,
            24,
            46
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p04-020-pbsc-24dk5",
      "family": "PBSC",
      "model": "PBSC-24DK5",
      "configuration": "Vertical water-to-air \u2014 scroll compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 4,
      "evidence": "[DC-HPM-p4:model-table] [DC-HPM-p4:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 4,
        "page_text": "sources/pages/page-04.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 24000,
          "heat_32f_btu": 20000,
          "cool_50f_btu": 26000,
          "cool_70f_btu": 23000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 24,
          "depth_in": 24,
          "height_in": 46
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-closeup.jpg",
      "representative_image_sha256": "a0d4b7f171affdb20d23a029810214cd3d416d638625ff76f70c385fe127ecd6",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            24,
            24,
            46
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p04-021-pbsc-20dk5",
      "family": "PBSC",
      "model": "PBSC-20DK5",
      "configuration": "Vertical water-to-air \u2014 scroll compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 4,
      "evidence": "[DC-HPM-p4:model-table] [DC-HPM-p4:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 4,
        "page_text": "sources/pages/page-04.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 20000,
          "heat_32f_btu": 17000,
          "cool_50f_btu": 22000,
          "cool_70f_btu": 19000,
          "cop_50f": "4.4",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 13000,
          "heat_32f_btu": 12000,
          "cool_50f_btu": 15000,
          "cool_70f_btu": 13000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 24,
          "depth_in": 24,
          "height_in": 46
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-closeup.jpg",
      "representative_image_sha256": "a0d4b7f171affdb20d23a029810214cd3d416d638625ff76f70c385fe127ecd6",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            24,
            24,
            46
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p04-022-pbsc-14dk5",
      "family": "PBSC",
      "model": "PBSC-14DK5",
      "configuration": "Vertical water-to-air \u2014 scroll compressor",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 4,
      "evidence": "[DC-HPM-p4:model-table] [DC-HPM-p4:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 4,
        "page_text": "sources/pages/page-04.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 16000,
          "heat_32f_btu": 14000,
          "cool_50f_btu": 18000,
          "cool_70f_btu": 16000,
          "cop_50f": "4.3",
          "cop_32f": "3.6",
          "source_seer_50f": "16.9",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 24,
          "depth_in": 24,
          "height_in": 46
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-vertical-closeup.jpg",
      "representative_image_sha256": "a0d4b7f171affdb20d23a029810214cd3d416d638625ff76f70c385fe127ecd6",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbsc",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            24,
            24,
            46
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p06-023-pbhs-96ds12k20",
      "family": "PBHS",
      "model": "PBHS-96DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 large",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 6,
      "evidence": "[DC-HPM-p6:model-table] [DC-HPM-p6:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 6,
        "page_text": "sources/pages/page-06.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 96000,
          "heat_32f_btu": 82000,
          "cool_50f_btu": 98000,
          "cool_70f_btu": 92000,
          "cop_50f": "4.0",
          "cop_32f": "3.6",
          "source_seer_50f": "16.8",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-compressor.jpg",
      "representative_image_sha256": "8bc960292f9d7781e069819c0c533fa1c2abd8417016c6d3511478d56d5f9cfc",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p06-024-pbhs-78ds12k20",
      "family": "PBHS",
      "model": "PBHS-78DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 large",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 6,
      "evidence": "[DC-HPM-p6:model-table] [DC-HPM-p6:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 6,
        "page_text": "sources/pages/page-06.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 78000,
          "heat_32f_btu": 68000,
          "cool_50f_btu": 84000,
          "cool_70f_btu": 78000,
          "cop_50f": "4.2",
          "cop_32f": "3.8",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.4"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-compressor.jpg",
      "representative_image_sha256": "8bc960292f9d7781e069819c0c533fa1c2abd8417016c6d3511478d56d5f9cfc",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p06-025-pbhs-68ds12k20",
      "family": "PBHS",
      "model": "PBHS-68DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 large",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 6,
      "evidence": "[DC-HPM-p6:model-table] [DC-HPM-p6:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 6,
        "page_text": "sources/pages/page-06.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 50000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 68000,
          "heat_32f_btu": 60000,
          "cool_50f_btu": 74000,
          "cool_70f_btu": 68000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-compressor.jpg",
      "representative_image_sha256": "8bc960292f9d7781e069819c0c533fa1c2abd8417016c6d3511478d56d5f9cfc",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p06-026-pbhs-64ds12k20",
      "family": "PBHS",
      "model": "PBHS-64DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 large",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 6,
      "evidence": "[DC-HPM-p6:model-table] [DC-HPM-p6:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 6,
        "page_text": "sources/pages/page-06.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 64000,
          "heat_32f_btu": 56000,
          "cool_50f_btu": 70000,
          "cool_70f_btu": 64000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-compressor.jpg",
      "representative_image_sha256": "8bc960292f9d7781e069819c0c533fa1c2abd8417016c6d3511478d56d5f9cfc",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-027-phhs-64ds12k20",
      "family": "PHHS",
      "model": "PHHS-64DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 42000,
          "heat_32f_btu": 38000,
          "cool_50f_btu": 47000,
          "cool_70f_btu": 43000,
          "cop_50f": "4.2",
          "cop_32f": "3.7",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.8"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 64000,
          "heat_32f_btu": 56000,
          "cool_50f_btu": 70000,
          "cool_70f_btu": 64000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-028-phhs-60ds12k20",
      "family": "PHHS",
      "model": "PHHS-60DS12K20",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 60000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 66000,
          "cool_70f_btu": 60000,
          "cop_50f": "4.1",
          "cop_32f": "3.7",
          "source_seer_50f": "17.2",
          "source_seer_70f": "16.3"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-029-phhs-56ds12k15",
      "family": "PHHS",
      "model": "PHHS-56DS12K15",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 37000,
          "heat_32f_btu": 34000,
          "cool_50f_btu": 40000,
          "cool_70f_btu": 37000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 56000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 60000,
          "cool_70f_btu": 56000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-030-phhs-55ds12k15",
      "family": "PHHS",
      "model": "PHHS-55DS12K15",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 55000,
          "heat_32f_btu": 49000,
          "cool_50f_btu": 59000,
          "cool_70f_btu": 55000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-031-phhs-48ds12k15",
      "family": "PHHS",
      "model": "PHHS-48DS12K15",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 48000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 49000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-032-phhs-46ds12k15",
      "family": "PHHS",
      "model": "PHHS-46DS12K15",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 31000,
          "heat_32f_btu": 26000,
          "cool_50f_btu": 31000,
          "cool_70f_btu": 29000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 38000,
          "cool_50f_btu": 47000,
          "cool_70f_btu": 44000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-033-phhs-40ds12k10",
      "family": "PHHS",
      "model": "PHHS-40DS12K10",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 26000,
          "heat_32f_btu": 23000,
          "cool_50f_btu": 28000,
          "cool_70f_btu": 26000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 40000,
          "heat_32f_btu": 34000,
          "cool_50f_btu": 42000,
          "cool_70f_btu": 38000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p07-034-phhs-34s12k10",
      "family": "PHHS",
      "model": "PHHS-34S12K10",
      "configuration": "Horizontal split water-to-air \u2014 standard",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 7,
      "evidence": "[DC-HPM-p7:model-table] [DC-HPM-p7:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 7,
        "page_text": "sources/pages/page-07.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 24000,
          "heat_32f_btu": 20000,
          "cool_50f_btu": 24000,
          "cool_70f_btu": 23000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 34000,
          "heat_32f_btu": 30000,
          "cool_50f_btu": 36000,
          "cool_70f_btu": 34000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 28
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": "photos/split-air-handler.jpg",
      "representative_image_sha256": "d9a97c3d306fbd1625cffb406e08a763d1c181aad5efe3f88bf75ce63efe8997",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "phhs",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            28
          ]
        },
        {
          "assembly": "phhs-air-handler",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            42,
            32,
            28
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p08-035-pbho-96ds12k20",
      "family": "PBHO/PHHO",
      "model": "PBHO-96DS12K20",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 83000,
        "heat_50f_btu": 96000,
        "heat_32f_btu": 82000,
        "cool_50f_btu": 98000,
        "cool_70f_btu": 92000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-036-pbho-78ds12k20",
      "family": "PBHO/PHHO",
      "model": "PBHO-78DS12K20",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 70000,
        "heat_50f_btu": 78000,
        "heat_32f_btu": 68000,
        "cool_50f_btu": 84000,
        "cool_70f_btu": 78000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-037-pbho-68ds12k20",
      "family": "PBHO/PHHO",
      "model": "PBHO-68DS12K20",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 60000,
        "heat_50f_btu": 68000,
        "heat_32f_btu": 60000,
        "cool_50f_btu": 74000,
        "cool_70f_btu": 68000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-038-pbho-64ds12k20",
      "family": "PBHO/PHHO",
      "model": "PBHO-64DS12K20",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 57000,
        "heat_50f_btu": 64000,
        "heat_32f_btu": 56000,
        "cool_50f_btu": 70000,
        "cool_70f_btu": 64000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-039-phho-56ds12k15",
      "family": "PBHO/PHHO",
      "model": "PHHO-56DS12K15",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 51000,
        "heat_50f_btu": 56000,
        "heat_32f_btu": 50000,
        "cool_50f_btu": 60000,
        "cool_70f_btu": 56000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-040-phho-55ds12k15",
      "family": "PBHO/PHHO",
      "model": "PHHO-55DS12K15",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 50000,
        "heat_50f_btu": 55000,
        "heat_32f_btu": 49000,
        "cool_50f_btu": 59000,
        "cool_70f_btu": 55000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-041-phho-48ds12k15",
      "family": "PBHO/PHHO",
      "model": "PHHO-48DS12K15",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 42000,
        "heat_50f_btu": 48000,
        "heat_32f_btu": 40000,
        "cool_50f_btu": 49000,
        "cool_70f_btu": 46000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-042-phho-46ds12k15",
      "family": "PBHO/PHHO",
      "model": "PHHO-46DS12K15",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 40000,
        "heat_50f_btu": 46000,
        "heat_32f_btu": 38000,
        "cool_50f_btu": 47000,
        "cool_70f_btu": 44000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-043-phho-40ds12k10",
      "family": "PBHO/PHHO",
      "model": "PHHO-40DS12K10",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 35000,
        "heat_50f_btu": 40000,
        "heat_32f_btu": 34000,
        "cool_50f_btu": 42000,
        "cool_70f_btu": 38000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p08-044-phho-34s12k10",
      "family": "PBHO/PHHO",
      "model": "PHHO-34S12K10",
      "configuration": "One-cabinet horizontal water-to-air \u2014 large/standard",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 8,
      "evidence": "[DC-HPM-p8:model-table] [DC-HPM-p8:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 8,
        "page_text": "sources/pages/page-08.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 30000,
        "heat_50f_btu": 34000,
        "heat_32f_btu": 30000,
        "cool_50f_btu": 36000,
        "cool_70f_btu": 34000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 72,
          "depth_in": 32,
          "height_in": 28
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section title says PHHO while first four rows use PBHO."
      ]
    },
    {
      "row_id": "p09-045-pbhc-34s12k10",
      "family": "PBHC",
      "model": "PBHC-34S12K10",
      "configuration": "One-cabinet horizontal water-to-air \u2014 compact",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 9,
      "evidence": "[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 9,
        "page_text": "sources/pages/page-09.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 30000,
        "heat_50f_btu": 34000,
        "heat_32f_btu": 30000,
        "cool_50f_btu": 36000,
        "cool_70f_btu": 34000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 66,
          "depth_in": 28,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "row_id": "p09-046-pbhc-26dk5",
      "family": "PBHC",
      "model": "PBHC-26DK5",
      "configuration": "One-cabinet horizontal water-to-air \u2014 compact",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 9,
      "evidence": "[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 9,
        "page_text": "sources/pages/page-09.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 20000,
        "heat_50f_btu": 22000,
        "heat_32f_btu": 19000,
        "cool_50f_btu": 24000,
        "cool_70f_btu": 21000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 66,
          "depth_in": 28,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "row_id": "p09-047-pbhc-24dk5",
      "family": "PBHC",
      "model": "PBHC-24DK5",
      "configuration": "One-cabinet horizontal water-to-air \u2014 compact",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 9,
      "evidence": "[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 9,
        "page_text": "sources/pages/page-09.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 18000,
        "heat_50f_btu": 20000,
        "heat_32f_btu": 17000,
        "cool_50f_btu": 23000,
        "cool_70f_btu": 20000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 66,
          "depth_in": 28,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "row_id": "p09-048-pbhc-20dk5",
      "family": "PBHC",
      "model": "PBHC-20DK5",
      "configuration": "One-cabinet horizontal water-to-air \u2014 compact",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 9,
      "evidence": "[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 9,
        "page_text": "sources/pages/page-09.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 15000,
        "heat_50f_btu": 17000,
        "heat_32f_btu": 14000,
        "cool_50f_btu": 18000,
        "cool_70f_btu": 16000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 66,
          "depth_in": 28,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "row_id": "p09-049-pbhc-14dk5",
      "family": "PBHC",
      "model": "PBHC-14DK5",
      "configuration": "One-cabinet horizontal water-to-air \u2014 compact",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 9,
      "evidence": "[DC-HPM-p9:model-table] [DC-HPM-p9:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 9,
        "page_text": "sources/pages/page-09.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 12000,
        "heat_50f_btu": 13000,
        "heat_32f_btu": 11000,
        "cool_50f_btu": 14000,
        "cool_70f_btu": 12000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 66,
          "depth_in": 28,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBHC-14DK5 appears twice with 12,000 and 8,600 Btu compressors; duplicate model identifier."
      ]
    },
    {
      "row_id": "p10-050-pbst-96ds12k20",
      "family": "PBST",
      "model": "PBST-96DS12K20",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 96000,
          "heat_32f_btu": 82000,
          "cool_50f_btu": 98000,
          "cool_70f_btu": 92000,
          "cop_50f": "4.0",
          "cop_32f": "3.6",
          "source_seer_50f": "16.8",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-051-pbst-78ds12k20",
      "family": "PBST",
      "model": "PBST-78DS12K20",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 78000,
          "heat_32f_btu": 68000,
          "cool_50f_btu": 84000,
          "cool_70f_btu": 78000,
          "cop_50f": "4.2",
          "cop_32f": "3.8",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.4"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-052-pbst-68ds12k20",
      "family": "PBST",
      "model": "PBST-68DS12K20",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 50000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 68000,
          "heat_32f_btu": 60000,
          "cool_50f_btu": 74000,
          "cool_70f_btu": 68000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-053-pbst-64ds12k20",
      "family": "PBST",
      "model": "PBST-64DS12K20",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 64000,
          "heat_32f_btu": 56000,
          "cool_50f_btu": 70000,
          "cool_70f_btu": 64000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-054-pbst-56ds12k15",
      "family": "PBST",
      "model": "PBST-56DS12K15",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 37000,
          "heat_32f_btu": 34000,
          "cool_50f_btu": 40000,
          "cool_70f_btu": 37000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 56000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 60000,
          "cool_70f_btu": 56000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-055-pbst-55ds12k15",
      "family": "PBST",
      "model": "PBST-55DS12K15",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 55000,
          "heat_32f_btu": 49000,
          "cool_50f_btu": 59000,
          "cool_70f_btu": 55000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-056-pbst-48ds12k15",
      "family": "PBST",
      "model": "PBST-48DS12K15",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 48000,
          "heat_32f_btu": 40000,
          "cool_50f_btu": 49000,
          "cool_70f_btu": 46000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p10-057-pbst-46ds12k15",
      "family": "PBST",
      "model": "PBST-46DS12K15",
      "configuration": "Vertical water-to-air triple function",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 10,
      "evidence": "[DC-HPM-p10:model-table] [DC-HPM-p10:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 10,
        "page_text": "sources/pages/page-10.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 31000,
          "heat_32f_btu": 26000,
          "cool_50f_btu": 31000,
          "cool_70f_btu": 29000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 46000,
          "heat_32f_btu": 38000,
          "cool_50f_btu": 47000,
          "cool_70f_btu": 44000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "source_family_envelope",
      "source_cabinet_options": [
        {
          "width_in": 28,
          "depth_in": 36,
          "height_in": 65
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/air-shop-coil.jpg",
      "representative_image_sha256": "e8f157983e8e7adde313aa997ecf46e12d41adb7db435636153bead884982aa4",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbst",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            28,
            36,
            65
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p11-058-pbht-96ds12k20",
      "family": "PBHT",
      "model": "PBHT-96DS12K20",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 83000,
        "heat_50f_btu": 96000,
        "heat_32f_btu": 82000,
        "cool_50f_btu": 98000,
        "cool_70f_btu": 92000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-059-pbht-78ds12k20",
      "family": "PBHT",
      "model": "PBHT-78DS12K20",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 70000,
        "heat_50f_btu": 78000,
        "heat_32f_btu": 68000,
        "cool_50f_btu": 84000,
        "cool_70f_btu": 78000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-060-pbht-68ds12k20",
      "family": "PBHT",
      "model": "PBHT-68DS12K20",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 60000,
        "heat_50f_btu": 68000,
        "heat_32f_btu": 60000,
        "cool_50f_btu": 74000,
        "cool_70f_btu": 68000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-061-pbht-56ds12k15",
      "family": "PBHT",
      "model": "PBHT-56DS12K15",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 51000,
        "heat_50f_btu": 56000,
        "heat_32f_btu": 50000,
        "cool_50f_btu": 60000,
        "cool_70f_btu": 56000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-062-pbht-55ds12k15",
      "family": "PBHT",
      "model": "PBHT-55DS12K15",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 50000,
        "heat_50f_btu": 55000,
        "heat_32f_btu": 49000,
        "cool_50f_btu": 59000,
        "cool_70f_btu": 55000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-063-pbht-48ds12k15",
      "family": "PBHT",
      "model": "PBHT-48DS12K15",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 42000,
        "heat_50f_btu": 48000,
        "heat_32f_btu": 40000,
        "cool_50f_btu": 49000,
        "cool_70f_btu": 46000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p11-064-pbht-46ds12k15",
      "family": "PBHT",
      "model": "PBHT-46DS12K15",
      "configuration": "Horizontal water-to-air triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 11,
      "evidence": "[DC-HPM-p11:model-table] [DC-HPM-p11:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 11,
        "page_text": "sources/pages/page-11.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 40000,
        "heat_50f_btu": 46000,
        "heat_32f_btu": 38000,
        "cool_50f_btu": 47000,
        "cool_70f_btu": 44000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        }
      ],
      "secondary_cabinet": {
        "width_in": 42,
        "depth_in": 32,
        "height_in": 28
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Cabinet paragraph says PSHT; 57,000-Btu row says PBST-64DS12K20 while the section and other rows say PBHT."
      ]
    },
    {
      "row_id": "p12-065-pbww-83ds12",
      "family": "PBWW",
      "model": "PBWW-83DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 83000,
          "heat_32f_btu": 74000,
          "cool_50f_btu": 80000,
          "cool_70f_btu": 72000,
          "cop_50f": "4.0",
          "cop_32f": "3.6",
          "source_seer_50f": "16.8",
          "source_seer_70f": "16.1"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-066-pbww-70ds12",
      "family": "PBWW",
      "model": "PBWW-70DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 70000,
          "heat_32f_btu": 62000,
          "cool_50f_btu": 68000,
          "cool_70f_btu": 62000,
          "cop_50f": "4.2",
          "cop_32f": "3.8",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.4"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-067-pbww-60ds12",
      "family": "PBWW",
      "model": "PBWW-60DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 39600,
          "heat_32f_btu": 35000,
          "cool_50f_btu": 37000,
          "cool_70f_btu": 34000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 60000,
          "heat_32f_btu": 53000,
          "cool_50f_btu": 57000,
          "cool_70f_btu": 51000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-068-pbww-57ds12",
      "family": "PBWW",
      "model": "PBWW-57DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 57000,
          "heat_32f_btu": 50000,
          "cool_50f_btu": 55000,
          "cool_70f_btu": 49500,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-069-pbww-51ds12",
      "family": "PBWW",
      "model": "PBWW-51DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 34000,
          "heat_32f_btu": 30000,
          "cool_50f_btu": 32000,
          "cool_70f_btu": 28500,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.9",
          "source_seer_70f": "17.1"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 51000,
          "heat_32f_btu": 44800,
          "cool_50f_btu": 48000,
          "cool_70f_btu": 43200,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-070-pbww-50ds12",
      "family": "PBWW",
      "model": "PBWW-50DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 50000,
          "heat_32f_btu": 44000,
          "cool_50f_btu": 48000,
          "cool_70f_btu": 44000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-071-pbww-42ds12",
      "family": "PBWW",
      "model": "PBWW-42DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Single stage",
          "heat_50f_btu": 42000,
          "heat_32f_btu": 36500,
          "cool_50f_btu": 40000,
          "cool_70f_btu": 36000,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-072-pbww-40ds12",
      "family": "PBWW",
      "model": "PBWW-40DS12",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 26400,
          "heat_32f_btu": 23200,
          "cool_50f_btu": 26000,
          "cool_70f_btu": 22400,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 40000,
          "heat_32f_btu": 35200,
          "cool_50f_btu": 38000,
          "cool_70f_btu": 34000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-073-pbww-30s12k10",
      "family": "PBWW",
      "model": "PBWW-30S12K10",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 19800,
          "heat_32f_btu": 17400,
          "cool_50f_btu": 18500,
          "cool_70f_btu": 16500,
          "cop_50f": "4.4",
          "cop_32f": "3.9",
          "source_seer_50f": "17.6",
          "source_seer_70f": "16.7"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 30000,
          "heat_32f_btu": 26400,
          "cool_50f_btu": 28000,
          "cool_70f_btu": 25000,
          "cop_50f": "4.3",
          "cop_32f": "3.8",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.5"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p12-074-pbww-20dk5",
      "family": "PBWW",
      "model": "PBWW-20DK5",
      "configuration": "Water-to-water",
      "spec_status": "VERIFIED_SPEC_SOURCE",
      "capacity_status": "source_table_not_independent_test",
      "source_page": 12,
      "evidence": "[DC-HPM-p12:model-table] [DC-HPM-p12:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 12,
        "page_text": "sources/pages/page-12.txt"
      },
      "source_stages": [
        {
          "label": "Step 1",
          "heat_50f_btu": 13200,
          "heat_32f_btu": 11600,
          "cool_50f_btu": 11800,
          "cool_70f_btu": 10500,
          "cop_50f": "4.6",
          "cop_32f": "3.9",
          "source_seer_50f": "17.4",
          "source_seer_70f": "16.8"
        },
        {
          "label": "Step 2",
          "heat_50f_btu": 20000,
          "heat_32f_btu": 17600,
          "cool_50f_btu": 18000,
          "cool_70f_btu": 16000,
          "cop_50f": "4.4",
          "cop_32f": "3.7",
          "source_seer_50f": "17.1",
          "source_seer_70f": "16.2"
        }
      ],
      "unresolved_printed_values": null,
      "unresolved_value_scope": null,
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 48,
          "depth_in": 42,
          "height_in": 31.5
        },
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 26
        }
      ],
      "secondary_cabinet": null,
      "representative_image": "photos/water-water-single.jpg",
      "representative_image_sha256": "8cb750ec2eca531616ad310cb5ca66741abe8c62ce74b502cffe5b23d6e42de3",
      "representative_image_status": "original_photo_exact_model_unconfirmed",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [
        {
          "assembly": "pbww",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            48,
            42,
            31.5
          ]
        },
        {
          "assembly": "pbww-compact",
          "status": "Cabinet envelope sourced; details inferred; internal layout conceptual",
          "cabinet_inches": [
            36,
            36,
            26
          ]
        }
      ],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": []
    },
    {
      "row_id": "p14-075-pwwt-83ds12",
      "family": "PWWT",
      "model": "PWWT-83DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 83000,
        "heat_50f_btu": 83000,
        "heat_32f_btu": 74000,
        "cool_50f_btu": 80000,
        "cool_70f_btu": 72000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-076-pwwt-70ds12",
      "family": "PWWT",
      "model": "PWWT-70DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 70000,
        "heat_50f_btu": 70000,
        "heat_32f_btu": 62000,
        "cool_50f_btu": 68000,
        "cool_70f_btu": 62000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-077-pwwt-60ds12",
      "family": "PWWT",
      "model": "PWWT-60DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 60000,
        "heat_50f_btu": 60000,
        "heat_32f_btu": 53000,
        "cool_50f_btu": 57000,
        "cool_70f_btu": 51000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-078-pwwt-57ds12",
      "family": "PWWT",
      "model": "PWWT-57DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 57000,
        "heat_50f_btu": 57000,
        "heat_32f_btu": 50000,
        "cool_50f_btu": 55000,
        "cool_70f_btu": 49500
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-079-pwwt-51ds12",
      "family": "PWWT",
      "model": "PWWT-51DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 51000,
        "heat_50f_btu": 51000,
        "heat_32f_btu": 44800,
        "cool_50f_btu": 48000,
        "cool_70f_btu": 43200
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-080-pwwt-50ds12",
      "family": "PWWT",
      "model": "PWWT-50DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 50000,
        "heat_50f_btu": 50000,
        "heat_32f_btu": 44000,
        "cool_50f_btu": 48000,
        "cool_70f_btu": 44000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-081-pwwt-42ds12",
      "family": "PWWT",
      "model": "PWWT-42DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 42000,
        "heat_50f_btu": 42000,
        "heat_32f_btu": 36500,
        "cool_50f_btu": 40000,
        "cool_70f_btu": 36000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p14-082-pwwt-40ds12",
      "family": "PWWT",
      "model": "PWWT-40DS12",
      "configuration": "Water-to-water triple function",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 14,
      "evidence": "[DC-HPM-p14:model-table] [DC-HPM-p14:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 14,
        "page_text": "sources/pages/page-14.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 40000,
        "heat_50f_btu": 40000,
        "heat_32f_btu": 35200,
        "cool_50f_btu": 38000,
        "cool_70f_btu": 34000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [],
      "secondary_cabinet": null,
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Four cabinet styles are mentioned but no model-to-cabinet mapping is provided."
      ]
    },
    {
      "row_id": "p15-083-pbdh-83ds12",
      "family": "PBDH",
      "model": "PBDH-83DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 83000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 86000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-084-pbdh-70ds12",
      "family": "PBDH",
      "model": "PBDH-70DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 70000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 73000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-085-pbdh-60ds12",
      "family": "PBDH",
      "model": "PBDH-60DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 60000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 64000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-086-pbdh-57ds12",
      "family": "PBDH",
      "model": "PBDH-57DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 57000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 60000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-087-pbdh-51ds12",
      "family": "PBDH",
      "model": "PBDH-51DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 51000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 54000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-088-pbdh-50ds12",
      "family": "PBDH",
      "model": "PBDH-50DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 50000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 53000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-089-pbdh-42ds12",
      "family": "PBDH",
      "model": "PBDH-42DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 42000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 44000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p15-090-pbdh-40ds12",
      "family": "PBDH",
      "model": "PBDH-40DS12",
      "configuration": "Indoor-pool dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 15,
      "evidence": "[DC-HPM-p15:model-table] [DC-HPM-p15:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 15,
        "page_text": "sources/pages/page-15.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 40000,
        "heat_50f_btu": null,
        "heat_32f_btu": null,
        "cool_70f_btu": null,
        "cool_86f_ewt_btu": 42000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications. Cooling column is printed 86F EWT, not 50F; the legacy interpreted key is corrected only in this export.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 65
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "PBDH-60DS12 step 1 is printed as 400,000 cooling Btu; retained only as an unresolved source error and not propagated."
      ]
    },
    {
      "row_id": "p16-091-pbsm-96ds12k20",
      "family": "PASD",
      "model": "PBSM-96DS12K20",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 83000,
        "heat_50f_btu": 96000,
        "heat_32f_btu": 82000,
        "cool_50f_btu": 98000,
        "cool_70f_btu": 92000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-092-pbsm-78ds12k20",
      "family": "PASD",
      "model": "PBSM-78DS12K20",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 70000,
        "heat_50f_btu": 78000,
        "heat_32f_btu": 68000,
        "cool_50f_btu": 84000,
        "cool_70f_btu": 78000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-093-pbsm-68ds12k20",
      "family": "PASD",
      "model": "PBSM-68DS12K20",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 60000,
        "heat_50f_btu": 68000,
        "heat_32f_btu": 60000,
        "cool_50f_btu": 74000,
        "cool_70f_btu": 68000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-094-pbsm-64ds12k20",
      "family": "PASD",
      "model": "PBSM-64DS12K20",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 57000,
        "heat_50f_btu": 64000,
        "heat_32f_btu": 56000,
        "cool_50f_btu": 70000,
        "cool_70f_btu": 64000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-095-pbve-56ds12k15",
      "family": "PASD",
      "model": "PBVE-56DS12K15",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 51000,
        "heat_50f_btu": 56000,
        "heat_32f_btu": 50000,
        "cool_50f_btu": 60000,
        "cool_70f_btu": 56000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-096-pbve-55ds12k15",
      "family": "PASD",
      "model": "PBVE-55DS12K15",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 50000,
        "heat_50f_btu": 55000,
        "heat_32f_btu": 49000,
        "cool_50f_btu": 59000,
        "cool_70f_btu": 55000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    },
    {
      "row_id": "p16-097-pbve-48ds12k15",
      "family": "PASD",
      "model": "PBVE-48DS12K15",
      "configuration": "Heating, cooling and absolute dehumidification",
      "spec_status": "UNVERIFIED_OPEN",
      "capacity_status": "unresolved_source_row",
      "source_page": 16,
      "evidence": "[DC-HPM-p16:model-table] [DC-HPM-p16:cabinet-dimensions]",
      "source_reference": {
        "document": "sources/dennis-product-specifications.pdf",
        "page": 16,
        "page_text": "sources/pages/page-16.txt"
      },
      "source_stages": [],
      "unresolved_printed_values": {
        "compressor_btu": 42000,
        "heat_50f_btu": 48000,
        "heat_32f_btu": 40000,
        "cool_50f_btu": 49000,
        "cool_70f_btu": 46000
      },
      "unresolved_value_scope": "Partial interpreted values only; use source_reference.page_text for the complete printed stages and qualifications.",
      "cabinet_status": "UNVERIFIED_OPEN_exact_cabinet",
      "source_cabinet_options": [
        {
          "width_in": 36,
          "depth_in": 36,
          "height_in": 64
        },
        {
          "width_in": 36,
          "depth_in": 34,
          "height_in": 59
        }
      ],
      "secondary_cabinet": {
        "width_in": 48,
        "depth_in": 42,
        "height_in": 31.5
      },
      "representative_image": null,
      "representative_image_sha256": null,
      "representative_image_status": "missing",
      "exact_model_image": null,
      "missing_exact_model_image": true,
      "cad_assemblies": [],
      "certification": "UNVERIFIED_OPEN",
      "electrical_selection": "UNVERIFIED_OPEN",
      "conflicts": [
        "Section is PASD but all visible row identifiers reuse PBSM/PBVE; page 16 ends mid-table."
      ]
    }
  ],
  "family_visualizations": [
    {
      "assembly": "pbsm",
      "family": "PBSM",
      "role": "vertical",
      "cabinet_inches": [
        28,
        36,
        64
      ],
      "source_page": 1,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbsm-front-right.png",
          "sha256": "2f5cd7148033b5adf436c3f9bcb907aa448511cd6b1f87a398fe24986678f179",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbsm-front.png",
          "sha256": "5496518029975ec920b222fa71cdc73c0af0e884a44f269807ac972167da7de1",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbsm-rear.png",
          "sha256": "df88425634fa16aa2604796ace27baec131b9a0182f407d8cf49fe59bef01dac",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbsm-cutaway.png",
          "sha256": "c65c994615e28077ff800ba948d872dd58d8180940268b85ff97a78b7f4be3d6",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbve",
      "family": "PBVE",
      "role": "vertical",
      "cabinet_inches": [
        28,
        34,
        59
      ],
      "source_page": 2,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbve-front-right.png",
          "sha256": "1d213faab5c56d43dc857d8985bf01be0a21f513642eaad9339736222fe97a0c",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbve-front.png",
          "sha256": "b66c60b2bd6a510cc6d122cecf1c3c6bfb9ba0f8e92f2a7260757fb12fdc367c",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbve-rear.png",
          "sha256": "357e1897a90156b12d11109ea8c0dd2586067aeb83fe31357b9fa4fb845f5e36",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbve-cutaway.png",
          "sha256": "96fad31e85064ae94490cd8c2c25e86b2a3730d51780d25d0809ffcb7635922f",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbmc",
      "family": "PBMC",
      "role": "vertical",
      "cabinet_inches": [
        26,
        26,
        54
      ],
      "source_page": 3,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbmc-front-right.png",
          "sha256": "bacdda6d452578b10211a55f835afcc9b064397ab183c87c1af6167a9fea6cd9",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbmc-front.png",
          "sha256": "424ee78729405f6df6ec042ede0e19e0bcc24fcf75eadf218911287af0046f8f",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbmc-rear.png",
          "sha256": "4185d58e93ce0beaf1c01e3fd265dea9d1104629868276b32d7287b9ce63d806",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbmc-cutaway.png",
          "sha256": "da477d037f0ff6a5f9ef0eb582a76365fe5448a1668af18db1719d104c0ae7a5",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbsc",
      "family": "PBSC",
      "role": "vertical",
      "cabinet_inches": [
        24,
        24,
        46
      ],
      "source_page": 4,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbsc-front-right.png",
          "sha256": "83d476e56695f37d5b96a22e9f61e238450b6801feb693126af655dcad1f392a",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbsc-front.png",
          "sha256": "00a41e53e6483d4cc8dde6b49a7ee776f5b0134149439baa37be7ee568b58ec8",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbsc-rear.png",
          "sha256": "eb6624b98581386ce3d5018ddbf7c8fe9012c78fd5d0e8673f453a8524627484",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbsc-cutaway.png",
          "sha256": "2eda498a41ebec64d2cd7479922d636d9b18fd85ceaa68761393d1500d14ac6b",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbhs",
      "family": "PBHS",
      "role": "compressor",
      "cabinet_inches": [
        48,
        42,
        31.5
      ],
      "source_page": 6,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbhs-front-right.png",
          "sha256": "5a9edd4737a6009022cd08847c9153fbe5b1684e2dc5011f471042e66bb7e59d",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbhs-front.png",
          "sha256": "fe04b5c212eb17b2585020468c82589d5c3e64719f144dc66e89a876b47d56b3",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbhs-rear.png",
          "sha256": "d4de3e81d759bf269d21ce30d2febdb794b592620f9e90b8342fdee2d881153e",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbhs-cutaway.png",
          "sha256": "e71b651a8e55dc4672bfe8f35ee19c89b8a957ba70aedf70be9a9e8dbd299f32",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbhs-air-handler",
      "family": "PBHS",
      "role": "handler",
      "cabinet_inches": [
        42,
        32,
        28
      ],
      "source_page": 6,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbhs-air-handler-front-right.png",
          "sha256": "31714415fcdd5a81cb52db7bc028ee797bcdeeaf2206727ce66a05da9aa26cfc",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbhs-air-handler-front.png",
          "sha256": "8cb16b65e216305a7db1049f118531362ed37bb14e0dda93cd041d203bda52c2",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbhs-air-handler-rear.png",
          "sha256": "0579bf2f707a6568fa764c42fafb84cb995d4073869b8e53cbb00c5111861fbb",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbhs-air-handler-cutaway.png",
          "sha256": "36652148b32d36fc722ee608cd2749d7446d9136ec451aa68490e76786bd87b2",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "phhs",
      "family": "PHHS",
      "role": "compressor",
      "cabinet_inches": [
        36,
        36,
        28
      ],
      "source_page": 7,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/phhs-front-right.png",
          "sha256": "d134e7dfb4a0ffb8d0612c125fd934216b7a047fd164c151a6ef3ee1639d6fd0",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/phhs-front.png",
          "sha256": "a00cdf5fe68dc3c2d325d80b0c1876b7922eeb41a9124536efc1f7f2ca0d2b5d",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/phhs-rear.png",
          "sha256": "48358cb7997ba508a90ca240bd3d3ccf1bcb9844d0fa37ae0bbf49344db3fc65",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/phhs-cutaway.png",
          "sha256": "631b24ad3130ac7045d081691bd2742e80540511af447ec806f021340b7d987b",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "phhs-air-handler",
      "family": "PHHS",
      "role": "handler",
      "cabinet_inches": [
        42,
        32,
        28
      ],
      "source_page": 7,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/phhs-air-handler-front-right.png",
          "sha256": "ee4dbd195de7ddb129bfdf5fc3d3ff12d655fc99d68a5c2121906a2d10c8cb25",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/phhs-air-handler-front.png",
          "sha256": "4f9a36790b9aaf91e16c2e6b65398848eca8fb39017542e2436aec204ce82a21",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/phhs-air-handler-rear.png",
          "sha256": "2619fd34756d8df8b3224cc10b8058a6b99b32c42a226a9861d6b2f104292cc3",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/phhs-air-handler-cutaway.png",
          "sha256": "c343d2b92fa0f26ab597ef5c27637608b9746f819fa493247647077ba78f2cf5",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbst",
      "family": "PBST",
      "role": "vertical",
      "cabinet_inches": [
        28,
        36,
        65
      ],
      "source_page": 10,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbst-front-right.png",
          "sha256": "6eb8beddcf38f8593c88492ff9f7b320f059093892b72397417d757cd758f9f6",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbst-front.png",
          "sha256": "18b8bd28ff50a3294fb2270a7017ed0bebbf777e7178aeb0dc944ac3425ebfc3",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbst-rear.png",
          "sha256": "465a621af884daedf3df8402b0422ff6459dc134aea7f3ad1ec7323d9882c57f",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbst-cutaway.png",
          "sha256": "da947f57e2ceeae2450fb564d61e7f87fd6c3a796caf778683bede5752af6ab5",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbww",
      "family": "PBWW",
      "role": "water",
      "cabinet_inches": [
        48,
        42,
        31.5
      ],
      "source_page": 12,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbww-front-right.png",
          "sha256": "9aec52e64f28b740d63c6a833d91950a8a197b8fb642412af6dc93f0f8678b82",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbww-front.png",
          "sha256": "dc76356f48673f5e96b8ba3d37d109ff06f21fa0eae8c0824d8debcc5621da6f",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbww-rear.png",
          "sha256": "e88205169b7506812dc58fe9fe1d5cf2eb1e67f6399779654b35f789253ac70b",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbww-cutaway.png",
          "sha256": "b61d3fada8f1faeeaac0534d10f8ea529e106e850cc71f6020ba7cdbc53d54d5",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    },
    {
      "assembly": "pbww-compact",
      "family": "PBWW",
      "role": "water",
      "cabinet_inches": [
        36,
        36,
        26
      ],
      "source_page": 12,
      "status": "source_family_envelope_internal_geometry_illustrative",
      "exact_model_geometry_verified": false,
      "views": {
        "front-right": {
          "file": "family-cad/pbww-compact-front-right.png",
          "sha256": "288dfbab6c97ad04df92047af5a6092f10fc70586b7364c4fd32acc112ae74f3",
          "width_px": 1400,
          "height_px": 1400
        },
        "front": {
          "file": "family-cad/pbww-compact-front.png",
          "sha256": "1ed3eee3c6343510c571b1a9bbbd0d6bd7b143190b1dc719d66619236b4c6d8c",
          "width_px": 1400,
          "height_px": 1400
        },
        "rear": {
          "file": "family-cad/pbww-compact-rear.png",
          "sha256": "33222dfc8d1dbacff625c1cc50929fbe3d2ba87fe37ebc1d072e18c50093d032",
          "width_px": 1400,
          "height_px": 1400
        },
        "cutaway": {
          "file": "family-cad/pbww-compact-cutaway.png",
          "sha256": "2e4eb3bfca8644a58489200d0f08837d0cd1c4079d0640fd7822313905952cce",
          "width_px": 1400,
          "height_px": 1400
        }
      }
    }
  ],
  "visualization_limit": "Legacy family cabinet studies only. Internal geometry is illustrative; PBSM height conflict and PBWW cabinet alternatives remain unresolved. Separate from the unbuilt modular concept. No exact-model render is approved."
}